Cone Flow Meters with Optional Diagnostic Capabilities

The Most Advanced DP Cone Flow Meter System on the Market

  • A modern Differential Pressure (DP) cone flow meter
  • Extremely immune to flow disturbances
  • Simple, Robust & Reliable
  • No moving parts
  • Low operating cost
  • Calibrated uncertainty up to 0.5%
  • Accurate, Repeatable & Cost Effective

DP Diagnostics Supplies a Unique, Powerful, Industrially Proven, Patent Pending Diagnostics System

Download PDF Brochure - Cone Flow Meters

Orifice Plate Flow Meter Diagnostics
   

DP Diagnostics Supplies Cone Flow Meters to All Industries

  • Size: 3" to 48" for any pipe schedule (larger sizes on request).
  • Flanges: #150 - #2500 (any specific connection on request)
  • Material: All standard materials available.
  • Length: Standard Cone flow meter is approximately 7D long.
  • DP Transmitter: Any DP transmitters may be used.
  • Calibration Requirements: Cone meters are supplied calibrated.
  • Installation Requirements: Between 0D - 3D upstream straight pipe length for most pipe configurations and equipment. 1D downstream straight pipe length required.
  • Performance: Cone flow meters are calibrated to give a discharge coefficient performance of up to ±0.5%. Turndowns of up to 10:1 without stacking transmitters .
Cone Flow Meter Diagnostics 2 Cone Flow Meter Diagnostics 3
DP Diagnostics Cone Meters Under
Standard & Non-Standard Testing.


Orifice Plate Flow Meter Diagnostics - Diagram 1
Cone Flow Meter with Optional Extra DP Transmitters
for Diagnostic Capabilities
Orifice Plate Flow Meter Diagnostics - Diagram 2
Pressure Field through the Cone Meter
Orifice Plate Flow Meter Diagnostics - Diagram 3
The Diagnostics Results are represented as 3 Points and a Box. If the points remain in the box, this ensures good flow measurement.
  • A Downstream Pressure Tap Allows 3 DP's to be Read.
  • The Pressure Field Through the Meter is Monitored.
  • The Diagnostic System Multiplies the Meters Capability.
  • 3 DP's are Compared to Assure Correct Meter Operation.
  • A Simple Live Diagnostics Plot is Shown in the Control Room.

Cone Flow Meter Problems that Produce a Warning with Diagnostics Include:

  1. Incorrect Inlet or Cone Diameter Keypad Entry.
  2. Two-Phase Flow.
  3. Debris Trapped at the Cone.
  4. Contamination Build-Up Through the Meter.
  5. Blocked Impulse Lines.
  6. Saturated or Drifting DP Transmitter.
  7. Incorrect Discharge Coefficient Keypad Entry.
  8. Incorrectly Spanned DP Transmitter.
  9. DP Below DP Transmitter Range.
  10. Damaged Cone Element. etc.

DP Diagnostics Can Retrofit a Diagnostic System to an Existing 3rd Party Cone Flow Meter if a Downstream Tap is Supplied and the Meter can be Made Available for Calibration.